Advanced imaging for bone research and materials science
A novel nano-tomography method developed by a team of researchers from the Technische Universität München TUM, the Paul Scherrer Institute PSI and the ETH Zurich opens the door to computed tomography examinations of minute structures at nanometer resolutions. The new method makes possible, for example, three-dimensional internal imaging of fragile bone structures. The first nano-CT images generated with this procedure was published in the renowned journal Nature on September 23, 2010. This new technique will facilitate advances in both life sciences and materials sciences.
Osteoporosis, a medical condition in which bones become brittle and fragile from a loss of density, is among the most common diseases in aging bones: According to the Swiss Osteoporosis Foundation, one in two women and one in four men over 50 will suffer a bone fracture caused by osteoporosis. Patients' bone material shrinks rapidly, leading to a significantly increased risk of fracture. In clinical research to date, osteoporosis is diagnosed almost exclusively by establishing an overall reduction in bone density. This approach, however, gives little information about the associated, and equally important, local structure and bone density changes. Franz Pfeiffer, TUM professor for Biomedical Physics and head of the research team, has resolved the dilemma: With our newly developed nano-CT method it is now possible to visualize the bone structure and density changes at high resolutions and in 3D. This enables us to do research on structural changes related to osteoporosis on a nanoscale and thus develop better therapeutic approaches.
During development, Pfeiffer’s team built on X-ray computed tomography (CT). The principle is well established – CT scanners are used every day in hospitals and medical practices for the diagnostic screening of the human body. In the process the human body is X-rayed while a detector records from different angles how much radiation is being absorbed. In principle it is nothing more than taking multiple X-ray pictures from various directions. A number of such pictures are then used to generate digital 3D images of the body's interior using image processing.
The newly developed method measures not only the overall beam intensity absorbed by the object under examination at each angle, but also those parts of the X-ray beam that are deflected in different directions – diffracted
in the language of physics. Such a diffraction pattern is generated for every point in the sample. This supplies additional information about the exact nanostructure, as X-ray radiation is particularly sensitive to the tiniest of structural changes. Because we have to take and process so many individual pictures with extreme precision, it was particularly important during the implementation of the method to use high-brilliance synchrotron-light and fast, low-noise pixel detectors – both available at the Swiss Light Source (SLS),
says Oliver Bunk, who was responsible for the requisite experimental setup at the PSI synchrotron facility in Switzerland.
The diffraction patterns are then processed using an algorithm developed by the team. TUM researcher Martin Dierolf, lead author of the Nature article, explains: We developed an image reconstruction algorithm that generates a high-resolution, three-dimensional image of the sample using over one hundred thousand diffraction patterns. This algorithm takes into account not only classical X-ray absorption, but also the significantly more sensitive phase shift of the X-rays.
A showcase example of the new technique was the examination of a 25-micrometer, superfine bone specimen of a laboratory mouse – with surprisingly exact results. The so-called phase contrast CT pictures show even smallest variations in the specimen’s bone density with extremely high precision: Cross-sections of cavities where bone cells reside and their roughly 100 nanometer-fine interconnection network are clearly visible.
Although the new nano-CT procedure does not achieve the spatial resolution currently available in electron microscopy, it can – because of the high penetration of X-rays – generate three-dimensional tomography images of bone samples,
comments Roger Wepf, director of the Electron Microscopy Center of the ETH Zurich (EMEZ). Furthermore, the new nano-CT procedure stands out with its high precision bone density measurement capacity, which is particularly important in bone research.
This method will open the door to more precise studies on the early phase of osteoporosis, in particular, and evaluation of the therapeutic outcomes of various treatments in clinical studies.
The new technique is also very interesting for non-medical applications: Further fields of application include the development of new materials in materials science or in the characterization of semiconductor components. Ultimately, the nano-CT procedure may also be transferred to novel, laser-based X-ray sources, such as the ones currently under development at the Cluster of Excellence Munich-Centre for Advanced Photonics
(MAP) and at the recently approved large research project Centre for Advanced Laser Applications
(CALA) on the TUM-Campus Garching near Munich.
About PSI
The Paul Scherrer Institute develops, builds and operates large-scale, complex research facilities, and makes these facilities available to the national and international research community. The Institute’s own research focuses on solid-state physics and the materials sciences, elementary particle physics, biology and medicine, as well as research involving energy and the environment. With a workforce of 1400 and an annual budget of about 300 million CHF, PSI is the largest research institution in Switzerland.
About ETH Zurich
The Eidgenössische Technische Hochschule Zürich (ETH Zurich) stands for excellence in teaching, groundbreaking basic research and the application of results to the benefit of society. Founded in 1855, today the ETH has over 15,000 students from approximately 80 countries, 3,400 of whom are doctoral candidates. As one of the leading international universities for technology and the natural sciences, it offers researchers an inspiring environment and students a comprehensive education. 21 Nobel laureates have studied, taught and conducted research at ETH Zurich, underscoring the excellent reputation of the institute.
About TUM
Technische Universitaet Muenchen (TUM) is one of Europe’s leading universities. It has roughly 420 professors, 7,500 academic and non-academic staff (including those at the university hospital “Rechts der Isar”), and 24,000 students. It focuses on the engineering sciences, natural sciences, life sciences, medicine, and economic sciences. After winning numerous awards, it was selected as an “Elite University” in 2006 by the Science Council (Wissenschaftsrat) and the German Research Foundation (DFG). The university’s global network includes an outpost in Singapore. TUM is dedicated to the ideal of a top-level research based entrepreneurial university.
Contacts
Prof. Dr. Franz Pfeiffer, Chair of Biomedical Physics, Technische Universität MünchenJames-Franck-Strasse 1, 85748 Garching, Germany
Tel.: +49 89 289 12551, Fax: +49 89 289 12548
E-Mail: nelly.de.leiris@mytum.de
Internet: http://www.physik.tu-muenchen.de/lehrstuehle/E17/
Dr. Oliver Bunk, Laboratory for Macromolecules and Bioimaging
Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
Tel.: +41 56 310 3077
E-Mail: oliver.bunk@psi.ch
Internet: www.psi.ch
Dr. Roger Albert Wepf, EMEZ – Electron Microscopy ETH Zurich
Wolfgang-Pauli-Str. 16, 8093 Zürich, Switzerland
Tel: +41 44 633 45 58
E-Mail: roger.wepf@emez.ethz.ch
Internet: www.ethz.ch
Original publication
Ptychographic X-Ray Computed Tomography at the Nano-ScaleMartin Dierolf, Andreas Menzel, Pierre Thibault, Philipp Schneider, Cameron M. Kewish, Roger Wepf, Oliver Bunk, Franz Pfeiffer:
Nature, 23. September 2010
DOI: 10.1038/nature09419
Animation
http://users.physik.tu-muenchen.de/gu45ten/franz_pfeiffer/bone_nanoCT.movThis animation shows the first nano-CT pictures of a bone sample with a diameter of about 25 micrometers. Clearly resolved are the fine, approximately 100-nanometer channels (canaliculi) that make up the interconnective network between the bone cells (osteocytes).